I Features:
This series machine for CNC dynamic column
Drilling And Milling Machine, the workpiece can be automatically and
continuously finished milling, drilling, boring, reaming, reaming, tapping
etc variety of processes in a fixture, The machine is suitable for procssing multi variety and
small batch of long plate, shell parts etc complex parts.
II.Main model and spec
Main specification
Unit
DZK5400
DZK3400
DZK1400
Worktable
size
mm
6000X500
4000X500
2000X500
Base to
worktable
mm
950
950
950
T Slot (no/width/gap)
mm
4/18/100
4/18100
4/18100
(X/Y/Z)
mm
5400/500/510
3400/500/510
1400/500/510
Distance
of spindle end to worktable surface
mm
190-700
Distance of spindle
center to the front column
mm
500
MAX loading of spindle
Kg
1000
ball screw size X/Y/Z
mm
80x12/50x10/40x10
X/Y/Z
Rapid
movement of X/Y/Z
m/min
15/15/10
Feeding
speed (Z axis)
;">mm/min
1-6000
">spindle hole
BT-40
Spindle
rotary speed
rpm
30-2000
;">
;">
Spindle
motor power
kw
AC3.7/5.5
tool capacity
hats
12
Toolselection
Any order selection
tool
change
No mechanical hand tool change
Max size of tool (dia and length)
mm
80x200
Max weight of tool
kg
8
Drilling capacity
mm
50
Max.
Torque of spindle
Nm
140
CNC Dynamic Column Drilling And Milling Machine Dynamic Column Drilling Milling Machine,CNC Column Drilling Milling Machine,Small Vertical Milling Machine,CNC Milling Machine NingXia DaHe Machine Tool (Group) Imp And Exp Co.,Ltd , http://www.nxdhjcmachine.com
Model: XJ5030Â Â Â Â Â Â Â Â Â
General Specifications
Tunnel Size : 500(W)×300(H)mm
Conveyor Speed: 0.22m/s
Conveyor Max Load: 150 kg
Single inspection dosage: < 1.32μGy
Leakage radiation <0.05μGy h
Wire Resolution: 0.0787mm metal line
Steel Penetration: 10MM
Film Safety: For ISO 1600
X-RAY GENERATOR
Orientation: Upward
Tube Current:0.4~0.7MA(adjustable)
Anode Voltage:80KV(adjustable)
Angle: 60°
Generator cooling/working periods:
Sealed oil bath with forced air/100%
OPERATING ENVIRONMENT
Storage Temperature: -20oC to 60oC
Operating Temperature: 0oC to 45oC
Relative Humidity:
20 to 95% non-condensing
System Power: 220 VAC (±10%) 50±3HZ
Power wastage: 1.0 KW (Max)
Noise<65DB
X-RAY Sensor:
L-shaped array detector
24bit
Single energy
Â
Image Performance System:
Display: High-resolution 19 inch color LCD display
Color quality: 24-Bit real colors based on materials
Edge enhancement: Object contour edge is more distinct
Super image enhancement: Image detail is more distinct
High penetration display: Increase the contrast of bright area in image to make the area that is easy to penetrate appear more clearly
Low penetration display: Increase the contrast of dark area in image to make the area that is difficult to penetrate appear more clearly.
Magnifier:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Partial magnifying function
Brightening/dimming:Â Â Â Â Â Â Increase/Decrease brightness of image
Image recurrence:Â Â Â Â Â Â Â Â Â Â Â Â Display the previous twenty images and process any one of them
Image restoration:Â Â Â Â Â Â Â Â Â Â Â Restore image to initial status
Image storage:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Real-time store any image and process it in operation status
Special features:
Sound alarm and simultaneous warning light alarm.
Network interface: Capable of connecting to LAN, and support multi-terminal check for baggage at same time
Safety ray: Ray is transmitted under automatic control, avoiding the error
One-key shutdown control: Just rotate the key to shut down the machine; it is safety, easy and convenient
Eagle eye: Capable of expediently observing the magnifying area
Self-diagnosis function: Give message automatically if malfunction for prompt maintenance
 Â
X-ray Luaggage Scanner for University,School,Office,Hotel,Bank
Model: XJ5030Â Â Â Â Â Â Â Â Â
General Specifications
Tunnel Size : 500(W)×300(H)mm
Conveyor Speed: 0.22m/s
Conveyor Max Load: 150 kg
Single inspection dosage: < 1.32μGy
Leakage radiation <0.05μGy h
Wire Resolution: 0.0787mm metal line
Steel Penetration: 10MM
Film Safety: For ISO 1600
X-RAY GENERATOR
Orientation: Upward
Tube Current:0.4~0.7MA(adjustable)
Anode Voltage:80KV(adjustable)
Angle: 60°
Generator cooling/working periods:
Sealed oil bath with forced air/100%
OPERATING ENVIRONMENT
Storage Temperature: -20oC to 60oC
Operating Temperature: 0oC to 45oC
Relative Humidity:
20 to 95% non-condensing
System Power: 220 VAC (±10%) 50±3HZ
Power wastage: 1.0 KW (Max)
Noise<65DB
X-RAY Sensor:
L-shaped array detector
24bit
Single energy
Â
Image Performance System:
Display: High-resolution 19 inch color LCD display
Color quality: 24-Bit real colors based on materials
Edge enhancement: Object contour edge is more distinct
Super image enhancement: Image detail is more distinct
High penetration display: Increase the contrast of bright area in image to make the area that is easy to penetrate appear more clearly
Low penetration display: Increase the contrast of dark area in image to make the area that is difficult to penetrate appear more clearly.
Magnifier:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Partial magnifying function
Brightening/dimming:Â Â Â Â Â Â Increase/Decrease brightness of image
Image recurrence:Â Â Â Â Â Â Â Â Â Â Â Â Display the previous twenty images and process any one of them
Image restoration:Â Â Â Â Â Â Â Â Â Â Â Restore image to initial status
Image storage:Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Â Real-time store any image and process it in operation status
Special features:
Sound alarm and simultaneous warning light alarm.
Network interface: Capable of connecting to LAN, and support multi-terminal check for baggage at same time
Safety ray: Ray is transmitted under automatic control, avoiding the error
One-key shutdown control: Just rotate the key to shut down the machine; it is safety, easy and convenient
Eagle eye: Capable of expediently observing the magnifying area
Self-diagnosis function: Give message automatically if malfunction for prompt maintenance
 Â
Model NO.: XJ5030
Conveyor Speed: 0.22m/S
Conveyor Max Load: 150kg
Wire Resolution: 40AWG
Steel Penetration: 10mm
Film Safety: ISO1600
Trademark: GUARD SPIRIT
Specification: ISO, CE, TUV
Origin: Shenzhen, China
HS Code: 9022
Model NO.: XJ5030
Conveyor Speed: 0.22m/S
Conveyor Max Load: 150kg
Wire Resolution: 40AWG
Steel Penetration: 10mm
Film Safety: ISO1600
Trademark: GUARD SPIRIT
Specification: ISO, CE, TUV
Origin: Shenzhen, China
HS Code: 9022
X-ray Luaggage Scanner for University,School,Office,Hotel,BankDecember 30, 2018