Dehydration is an indispensable process for wet beneficiation . Dehydration has concentrate dehydration, tailings dehydration, washing and dehydration. Concentrate dewatering can accurately control concentrate water and reduce concentrate loss; tailings dewatering is to reduce discharge, reduce energy consumption, and recycle process water; washing ore is used to recover valuable materials in fine mud, improve recovery rate and reduce Energy consumption. According to the process requirements, the computer is used for dehydration process control. The control system implements the following detection and control. The control system software consists of four functional modules. The functional modules are organically connected by the main program to form a complete dehydration control software. (3) Dehydration process parameters
KC/KWB series Industrial Chiller is mainly applied in Plastic & Rubber industry; it can accurately control the molding temperature and shorten the molding cycle, increase the product quality and improve the production efficiency. They are also widely used in Metal working, Mechanical & Engineering, Chemical & Pharmaceutical, Food & Beverage, Laser, Electronics industry, Textile, Electroplate, Semi-conductor testing, Water jet, Vacuum coating, Construction and Military.
Design features
¨ Adopted world famous brand compressors and high efficiency condenser and evaporator, ensure high cooling efficiency, low energy consumption, low noise and long service life.
¨ Chilled water temperature range 5℃ to 35℃.
¨ R22 charged, CFC free type R407C, R410A, R404A, R134A for option, high cooling efficiency.
¨ Over sized evaporator and condenser ensure the chiller unit running under 45C high ambient temperature.
¨ Microcomputer control system offering accurate temperature stability within ±1℃.
¨ Low noise and big volume air blower.
¨ Standard equipped Iron pump, stainless steel or high lift pump for option.
¨ Multi-protection devices ensure the chiller unit running safely.
¨ The innovative evaporator-in-tank configuration ensures a steady water temperature offered, as the evaporator also cools the tank itself, reduces ambient heat gain, and increases the efficiency.
¨ KWB Water Cooled Industrial Chiller adopted shell and tube condenser, features speed heat dissipation and high cooling efficiency, it is good to be used in High ambient temperature area with abundant water.
¨ KC Air Cooled Industrial Chiller adopted aluminum fin/copper tube type condenser, easy for cleaning and installation.
¨ Power supply: 1PH 220V/50HZ-----1/2HP to 2HP
3PH 380V/415V 50HZ-----3HP to 60HP
Industrial Refrigerator,Industrial Air Cooled Chiller,Air Cooled Industrial Refrigerator,Air Cooled Industrial Ice Water Machine Shenzhen city KayDeli Refrigeration Equipment Co.,Ltd. , https://www.kaydelichiller.com
The dehydration process consists of three main stages of concentration, filtration and drying. Concentration to increase filtration efficiency, drying to further reduce moisture, drying process is less used in China's mineral processing process.
Concentrate dewatering is accomplished in three stages: concentration, filtration and drying, depending on the water content of the final product. Concentrated dewatering and filtration dewatering are carried out in a concentrator and a filter, respectively.
Concentrate dewatering not only can accurately control concentrate water and reduce energy consumption, but also reduce the labor intensity of workers and improve working conditions.
(1) Process requirements and control purposes
A lead-zinc ore beneficiation dehydrated by a vacuum pump system, thickener, of discharge valves, lift pump pulp, dewatering filter, concentrate electronic scales, turn on the water drain tank and other equipment. The connection diagram of the dewatering section equipment is shown in Figure 1. The dewatering operation adopts an intermittent working system, and the driving or parking is determined according to the concentration of the bottom stream of the thickener and the amount of the mineral in the concentration tank.
(1) Monitoring and control of the concentration of the bottom stream of the concentration tank. When the limit is exceeded, the alarm can be automatically issued to ensure the safe operation of the transmission system of the concentration tank.
(2) Detection of the amount of minerals at the bottom of the concentrator.
(3) Opening and closing control of the discharge valve, fault detection and alarm.
(4) Detection and alarm of the level of the ore tank in the filter.
(5) The opening and closing control of the filter and its auxiliary equipment.
(6) Slurry lifting pump pool overflow detection and alarm.
(7) Weighing, data processing and report output of the concentrate products of the six filters. [next]
(2) Control system constitutes the microcomputer control system by ZD-065II basic system (including 4KB monitoring, 8KBBASIC, 4KB assembly, 4KB application, etc., the program is solidified in EPPOM), tape drive, terminal, CRT, printer, power supply, etc. composition. The digital input and output are isolated by optocoupler. The system block diagram is shown in Figure 2.
A Input operation module All control parameters, set values, initialization programs, etc. are completed in the input operation block.
B interface function module Analog input signal, digital input/output signal, real-time clock interrupt processing signal, etc., through the parallel interface to complete the input and output control functions. The interface function module consists of 45 function subroutines. Each subroutine is compiled in assembly language and hardened on the interface function block.
C Data processing module Used for data processing after A/D sampling, various condition discrimination and concentrate calculation. [next]
D Output control module Complete single-key Chinese character display, time display, fault display, and test data printout.
The control program is compiled in a combination of assembly language and BASIC language. The functional modules related to the interface are programmed in assembly language, and the subprograms and main programs that are related to the user are programmed in BASIC language. This solves the problem of the speed at which the outside world exchanges information with the host, facilitating human-machine dialogue. The system also has diagnostic and self-diagnostics. The control system software is shown in Figure 3.
In the dehydration control system, the simulated quantity detected has the concentration of the bottom stream of the concentration tank, the amount of the bottom of the thickener, and the weight of the concentrate.
A. Determination of the concentration of the bottom stream of the concentration tank During the concentration process of the slurry, the change of the concentration of the bottom layer of the slurry makes the input power of the drive motor of the thickener change significantly, which can indirectly reflect the change of the concentration of the slurry.
The input power is low, the slurry concentration is low, the filter cake is thin and ventilated during filtration, the dehydration effect is not good, and the filter cloth is wasted. The input power is high, the concentration of the slurry is high, and the concentration is too high, which is easy to block the pipeline and damage the transmission shaft and the transmission gear. Therefore, the concentration of the slurry in the compression zone of the concentrator is used to control the ore discharge valve, the slurry lift pump, and the dewatering filtration.
B. Concentration detection at the bottom of the concentrator The concentrate at the bottom of the concentrator is detected by injecting a small amount of water through the valve in the steel pipe to balance the water level in the pipe with the pressure of the slurry in the concentrator. Since the concentrator has a fixed volume, if the internal ore volume changes, the pressure on the bottom will change. In this way, the mineral amount is measured indirectly by a pressure transmitter.
C Concentrate weight detection Dehydrated lead, zinc, sulfur and other concentrate products are weighed separately by electronic scales. Switched by a pressure sensor.
When the concentrates are weighed to the set value, the microcomputer automatically detects the total weight and sends out the unloading concentrate signal. When the concentrate is poured into the concentrate bin, the concentrate is automatically tested for tare weight. Finally, after data processing, the concentrate output of each class is printed periodically.
In the process of analog quantity detection, random sampling, analog/digital conversion, etc. were carried out for the bottom stream concentration signals of lead, zinc and sulfur, the bottom quantity signal of the lead concentrator and the concentrate weight signal of six concentrates. And data processing, and take appropriate anti-interference measures. [next]
D The switch input signal detects the liquid level signal in the filter tank of the dehydration process, the alarm liquid level signal, the super-weight signal of the slurry lift pump box, the position signal of the mine discharge valve, the status signal of the concentrate scale, etc., which are detected by the microcomputer. Logical discrimination, participation in dehydration process control.
The liquid level alarm electrode in the filter tank is damaged, the slurry of the sand pump box overflows, the mine door cannot be opened or closed, and the report detection is installed in the system. The display automatically displays the measurement result, and the alarm output circuit outputs the alarm signal and the fault location in time. At the same time, the safety measures such as automatically or manually closing the mine valve are adopted to avoid the occurrence of run, run and leak of the concentrate during the dehydration process.
(4) Dehydration process control method
The main control of the system includes: start and stop control of the filter, liquid level control of the slurry lifting pump box, opening and closing control of the ore discharging valve, and eight-way alarm control signals issued during the dehydration control process.
A Concentrator bottom flow concentration and ore control When the underflow concentration and ore amount meet the specified value, the ore control is carried out. Mining conditions:
Y=A•B•C•D
Where A———concentrator power, upper limit ≥A> lower limit;
B———concentration of the concentrator, upper limit ≥ B> lower limit;
C———The slurry raises the pump tank level, C≤ lower limit value;
D———Filter liquid level, upper limit>D.
When the conditions are met, the ore discharge valve is opened in turn, the sand pump is started, the slurry is fed into the filter, and the process of dehydration of the concentrate is entered.
B Liquid level control and alarm in the filter tank The liquid level is too high, which will affect the dewatering effect. The liquid level is too low and is also detrimental to dehydration.
C Concentrate scale control Concentrate scale control is carried out when the amount of concentrate after dewatering reaches the set value.
D The slurry level of the pump lift pump tank is controlled. When the liquid level of the sand pump box is lower than the lower limit electrode, the discharge valve is opened, the sand pump is started, and the filter is discharged to the filter. When the liquid level of the sand pump box is at the upper limit, the ore discharge must be closed. valve. Above the upper limit, an alarm is displayed to prevent slurry overflow.
E The alarm control system dehydration process occurs when the lead, zinc, sulfur concentrate machine power over limit signal, sand pump box overweight signal, filter internal electrode fault signal, mine valve fault signal, concentrate scale full load signal, etc. The corresponding set values ​​in the memory are compared, and the sound and light alarm is output through the switch quantity, and the fault is processed in time to ensure the normal operation of the dehydration process.
(V) Main features of the control system The control system mainly has the following characteristics:
(1) The system uses reliable isolation technology in the input/output to solve the problem of on-site interference.
(2) A modular structure is adopted in software design. It adopts assembly language and BASIC language cross programming, which is more flexible and convenient.
(3) After adopting the system, the lead filtration efficiency of the plant is increased by 3.1 times, zinc is increased by 1.6 times, the water content of lead concentrate is reduced by 2 to 10%, and the water content of 11% zinc concentrate is reduced by 0.5 to 7.5%, reaching 13%. Better efficiency.
November 27, 2019