Highlights  Main performances of the lining materials Lining material Main Performance Applications Teflon 1.The most steady material in plastics which is resistible to boiling hydrochloric acid, vitriol fortis as well as strong alkali and organic impregnates.     Strong corrosive mediums such as strong acid and alkali F46 1.Have the same abrasion resistance with PTFE. 1.The same as PTFE. Neoprene 1.Be of good elasticity, retractility and abrasion resistance. Water, sewage and slurry, mineral serosity of low abrasion. Polyurethane 1.Be of good abrasion resistibility. Applicable in mineral serosity, slurry and coal slurry of high abrasion.  Main performances of the electrode materials Electrode material  Applications Stainless steel SS316 Applicable in water, sewage and corrosive mediums. Widely used in industries of petrol, chemistry, carbamide, etc. Hastelloy B(HB) Having strong resistance to hydrochloric acid of any consistence which is below boiling point. Also resistible against vitriol, phosphate, hydrofluoricacid,organic acid etc which are oxidable acid, alkali and non-oxidable salt. Hastelloy C(HC) Be resistant to oxidable acid such as nitric acid, mixed acid as well as oxidable salt such as Fe+++,Cu++and sea water Titanium Applicable in seawater, and kinds of chloride, hypochlorite salt, oxidable acid (including fuming nitric acid), organic acid, alkali etc. Not resistant to a pure reducing acid(such as sulphuric acid, hydrochloric acid)corrosion. But if acid contains antioxidant(such as Fe+++,Cu++) is greatly reduce corrosion. Tantalum Having strong resistance to corrosive mediums that is similar with glass. Almost applicable in all chemical mediums. Except for hydrofluoric acid, oleum and alkali. Platinum-iridium Almost be applicable in all chemical mediums except for aqua fortis, ammonium salt. Car And Motorcycle Tire Repair Tools Car And Motorcycle Tire Repair Tools,Professional Tire Patch Kit,Commercial Truck Tire Repair Kit,Semi Truck Tire Repair Tools KRONYO United Co., Ltd. , https://www.taibeikronyo.com
--Site digital LCD displays instantaneous flow, accumulative flow, flow rate.Â
--Various types provided according to specific conditions.
Item
LCD Electromagnetic Flow Meter for Industrial Waste Water
Applicable pipe size
DN 15-800 (1/2'' to 31-1/2'')
Applicable media
liquid with conductivity > 5 uS / cm
Velocity range
0.2~8 m/s (0.66 to 26.2 ft/s)
Accuracy
0.5%FS, 1.0%FSÂ
Process connection
flange, ANSI / GB / JIS, 1.0MPa, 1.6MPa, 4.0MPa, 16MPa optional
Processing temperature
-20 to 150°C, according to lining material
Ambient condition
-40 to 80°C, relative humidity <95%
Power supply
AC220V, 50Hz / DC24V / battery
Display
backlight LCD
Operation
4 light touch buttons
Signal output
4-20mA, loading resistance 750Ω,
pulse, 0-3kHz, 5V, RS485
Consumption
<8W
Cable inlet/outlet
M20*1.5
Protection
transducer IP68, converter IP65
Tube material
carbon steel, stainless steel optional
Lining material
PTFE, rubber, polyurethane, F46, Fs optional
Electrode material
stainless steel, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum optional
Grounding
made into a third electrode, same material with electrode
Industries
chemical, environmental, metallurgical, pharmaceutical, papermaking, water supply and drainage, etc.
2.Not be perfect in abrasion resistance.
2.Resistable for low abrasion.
3.Having strong resistance to load pressure.
2.Applicable in mediums of low abrasion.
2.Be resistant to low acid, alkali and salt but not for oxidation mediums.
2.Not be perfect in acid/alkali resistance.
3.Can't be used for water mixed with organic impregnants.
If you are interested in LCD electromagnetic flow meter for industrial waste, please call our office at +86-(0)21-5869 6328.
Alternatively, you can send us an email or use the contact form which can be found on the contact page of our website.
Model NO.: A+E 81F
Measuring Media: Liquid
Measuring Principle: Electrical Principles
Measurement Object: Closed Pipeline
Certification: ISO
Velocity Range: 0.2~8m/S
Electrode: 316L, Hc, Hb, Ti, Ta
Output: 4-20mA DC, Pulse, RS485
Pressure: Max.16 MPa
Media Temperature: Max 180 C (356 F)
Ambient Temperature: Sensor 80 C(176 F), Converter 50 C(120 F)
Power Supply: 220VAC or 24VDC
Consumption: <8W
Grounding: Made Into The Third Electrode
Trademark: AEAD
Origin: Shanghai
HS Code: 9026100000
LCD Electromagnetic Flow Meter for Industrial Waste Water--Large choice of liner materials suitable for drinking water, wastewater, chemicals and other liquids.
--Suitable for use in custody transfer applications.
--Measurement is independent of the flow profile.
--Abrasion and corrosion-resistant liners available.
--Electric conductivity of medium can be used for detection of product change.
--No additional pressure loss.
--No moveable parts and long working life.
--Two-way measurement system to detect the positive and negative flow.
--Change the grounding as the third electrode.
Â
Applications
--water and sewage treatment
--industrial chemical fluids
--viscous fluids
--slurries
--process flow control
Â
Parameters
Â